  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en",
    "notes": [
      {
        "category": "summary",
        "text": "RUGGEDCOM CROSSBOW Station Access Controller (SAC) contains multiple vulnerabilities in the integrated SQLite component that could allow an attacker to execute arbitrary code, cause a denial of service, or obtain sensitive information.\n\nSiemens has released a new version for RUGGEDCOM CROSSBOW Station Access Controller (SAC) and recommends to update to the latest version.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-765416: Multiple SQLite Vulnerabilities in RUGGEDCOM CROSSBOW Station Access Controller - HTML Version",
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-765416.html"
      },
      {
        "category": "self",
        "summary": "SSA-765416: Multiple SQLite Vulnerabilities in RUGGEDCOM CROSSBOW Station Access Controller - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-765416.json"
      }
    ],
    "title": "SSA-765416: Multiple SQLite Vulnerabilities in RUGGEDCOM CROSSBOW Station Access Controller",
    "tracking": {
      "current_release_date": "2026-10-13T00:00:00.000Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-765416",
      "initial_release_date": "2026-10-13T00:00:00.000Z",
      "revision_history": [
        {
          "date": "2026-10-13T00:00:00.000Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        }
      ],
      "status": "interim",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:intdot/<6.0",
                "product": {
                  "name": "RUGGEDCOM CROSSBOW Station Access Controller (SAC) < V6.0",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "RUGGEDCOM CROSSBOW Station Access Controller (SAC)"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2025-6965",
      "cwe": {
        "id": "CWE-197",
        "name": "Numeric Truncation Error"
      },
      "notes": [
        {
          "category": "description",
          "text": "There exists a vulnerability in SQLite versions before 3.50.2 where the number of aggregate terms could exceed the number of columns available. This could lead to a memory corruption issue. We recommend upgrading to version 3.50.2 or above.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V6.0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/110006651/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:H/A:L",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2025-6965"
    },
    {
      "cve": "CVE-2025-70873",
      "cwe": {
        "id": "CWE-244",
        "name": "Improper Clearing of Heap Memory Before Release ('Heap Inspection')"
      },
      "notes": [
        {
          "category": "description",
          "text": "An information disclosure issue in the zipfileInflate function in the zipfile extension in SQLite v3.51.1 and earlier allows attackers to obtain heap memory via supplying a crafted ZIP file.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V6.0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/110006651/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2025-70873"
    },
    {
      "cve": "CVE-2025-71316",
      "cwe": {
        "id": "CWE-176",
        "name": "Improper Handling of Unicode Encoding"
      },
      "notes": [
        {
          "category": "description",
          "text": "SQLite 'sqldiff.exe' does not securely handle the way the Microsoft Windows C runtime converts Unicode characters to ANSI codepages.  An attacker could use the '-L' option to load an arbitrary DLL with a crafted command line argument string that results in command line file arguments being misinterpreted as command line options. Fixed on or around 2025-12-26.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V6.0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/110006651/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2025-71316"
    },
    {
      "cve": "CVE-2026-11822",
      "cwe": {
        "id": "CWE-122",
        "name": "Heap-based Buffer Overflow"
      },
      "notes": [
        {
          "category": "description",
          "text": "SQLite before 3.53.2 contains memory corruption vulnerabilities in the FTS5 full-text search extension that allow attackers to cause process crashes, memory exhaustion, or arbitrary code execution by supplying a crafted database with malformed FTS5 page data. Attackers can trigger an out-of-bounds read in fts5LeafSeek() via an attacker-controlled loop bound and a heap buffer overflow write in fts5ChunkIterate() through a crafted continuation page causing an integer underflow, exploitable when an FTS5 MATCH query is executed against the malicious database.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V6.0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/110006651/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2026-11822"
    },
    {
      "cve": "CVE-2026-11824",
      "cwe": {
        "id": "CWE-122",
        "name": "Heap-based Buffer Overflow"
      },
      "notes": [
        {
          "category": "description",
          "text": "SQLite before 3.53.2 contains a heap-based buffer overflow vulnerability in the FTS5 full-text search extension that allows attackers to cause a crash or execute arbitrary code by supplying a crafted database with malicious continuation page metadata specifying a szLeaf value smaller than 4. Attackers can trigger an integer underflow in fts5ChunkIterate() causing an inflated remaining byte count during FTS5 MATCH query processing, leading to a heap buffer overflow of attacker-controlled data in applications compiled with SQLITE_ENABLE_FTS5.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V6.0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/110006651/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2026-11824"
    }
  ]
}