  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en",
    "notes": [
      {
        "category": "summary",
        "text": "SIPORT before V3.4.0 contains a privilege escalation vulnerability which could allow a local attacker with an unprivileged account to override or modify the service executable and subsequently gain elevated privileges.\n\nSiemens has released a new version for SIPORT and recommends to update to the latest version.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-064257: Privilege Escalation Vulnerability in SIPORT Before V3.4.0 - HTML Version",
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-064257.html"
      },
      {
        "category": "self",
        "summary": "SSA-064257: Privilege Escalation Vulnerability in SIPORT Before V3.4.0 - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-064257.json"
      }
    ],
    "title": "SSA-064257: Privilege Escalation Vulnerability in SIPORT Before V3.4.0",
    "tracking": {
      "current_release_date": "2024-11-12T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-064257",
      "initial_release_date": "2024-11-12T00:00:00Z",
      "revision_history": [
        {
          "date": "2024-11-12T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        }
      ],
      "status": "interim",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/<V3.4.0",
                "product": {
                  "name": "SIPORT",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "SIPORT"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2024-47783",
      "cwe": {
        "id": "CWE-732",
        "name": "Incorrect Permission Assignment for Critical Resource"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The affected application improperly assigns file permissions to installation folders.\r\n\r\nThis could allow a local attacker with an unprivileged account to override or modify the service executables and subsequently gain elevated privileges.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Remove write permissions for non-administrative users on files and folders located under the installation path",
          "product_ids": [
            "1"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.4.0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109826608/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2024-47783"
    }
  ]
}