  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited.",
      "tlp": {
        "label": "WHITE"
      }
    },
    "notes": [
      {
        "category": "summary",
        "text": "Teamcenter is affected by two security vulnerabilities in the File\nService Cache service that could lead to command injection and denial\nof service issues.     Siemens has released updates for the affected\nproducts and recommends to update to the latest versions.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens' operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-759952: Command Injection and Denial of Service Vulnerability in Teamcenter - PDF Version",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-759952.pdf"
      },
      {
        "category": "self",
        "summary": "SSA-759952: Command Injection and Denial of Service Vulnerability in Teamcenter - TXT Version",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-759952.txt"
      },
      {
        "category": "self",
        "summary": "SSA-759952: Command Injection and Denial of Service Vulnerability in Teamcenter - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-759952.json"
      }
    ],
    "title": "SSA-759952: Command Injection and Denial of Service Vulnerability in Teamcenter",
    "tracking": {
      "current_release_date": "2022-08-09T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-759952",
      "initial_release_date": "2022-08-09T00:00:00Z",
      "revision_history": [
        {
          "date": "2022-08-09T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        }
      ],
      "status": "final",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "< V12.4.0.15",
                "product": {
                  "name": "Teamcenter V12.4",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "Teamcenter V12.4"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "< V13.0.0.10",
                "product": {
                  "name": "Teamcenter V13.0",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "Teamcenter V13.0"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "< V13.1.0.10",
                "product": {
                  "name": "Teamcenter V13.1",
                  "product_id": "3"
                }
              }
            ],
            "category": "product_name",
            "name": "Teamcenter V13.1"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "< V13.2.0.9",
                "product": {
                  "name": "Teamcenter V13.2",
                  "product_id": "4"
                }
              }
            ],
            "category": "product_name",
            "name": "Teamcenter V13.2"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "< V13.3.0.5",
                "product": {
                  "name": "Teamcenter V13.3",
                  "product_id": "5"
                }
              }
            ],
            "category": "product_name",
            "name": "Teamcenter V13.3"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "< V14.0.0.2",
                "product": {
                  "name": "Teamcenter V14.0",
                  "product_id": "6"
                }
              }
            ],
            "category": "product_name",
            "name": "Teamcenter V14.0"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2022-34660",
      "cwe": {
        "id": "CWE-77",
        "name": "Improper Neutralization of Special Elements used in a Command ('Command Injection')"
      },
      "notes": [
        {
          "category": "summary",
          "text": "File Server Cache service in Teamcenter consist of a functionality that is vulnerable to command injection. This could potentially allow an attacker to perform remote code execution.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Harden the application\u2019s host to prevent local access by untrusted\npersonnel",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6"
          ]
        },
        {
          "category": "mitigation",
          "details": "Limit access to port 4544/tcp to specific IP addresses, e.g. with a\nfirewall",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6"
          ]
        },
        {
          "category": "no_fix_planned",
          "details": "Currently no fix is planned",
          "product_ids": [
            "5"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V12.4.0.15 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.0.0.10 or later version",
          "product_ids": [
            "2"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.10 or later version",
          "product_ids": [
            "3"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.2.0.9 or later version",
          "product_ids": [
            "4"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.3.0.5 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V14.0.0.2 or later version",
          "product_ids": [
            "6"
          ],
          "url": "https://support.sw.siemens.com/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.6,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6"
          ]
        }
      ],
      "title": "CVE-2022-34660"
    },
    {
      "cve": "CVE-2022-34661",
      "cwe": {
        "id": "CWE-835",
        "name": "Loop with Unreachable Exit Condition ('Infinite Loop')"
      },
      "notes": [
        {
          "category": "summary",
          "text": "File Server Cache service in Teamcenter is vulnerable to denial of service by entering infinite loops and using up CPU cycles. This could allow an attacker to cause denial of service condition.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Harden the application\u2019s host to prevent local access by untrusted\npersonnel",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6"
          ]
        },
        {
          "category": "mitigation",
          "details": "Limit access to port 4544/tcp to specific IP addresses, e.g. with a\nfirewall",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6"
          ]
        },
        {
          "category": "no_fix_planned",
          "details": "Currently no fix is planned",
          "product_ids": [
            "5"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V12.4.0.15 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.0.0.10 or later version",
          "product_ids": [
            "2"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.10 or later version",
          "product_ids": [
            "3"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.2.0.9 or later version",
          "product_ids": [
            "4"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.3.0.5 or later version",
          "product_ids": [
            "5"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V14.0.0.2 or later version",
          "product_ids": [
            "6"
          ],
          "url": "https://support.sw.siemens.com/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6"
          ]
        }
      ],
      "title": "CVE-2022-34661"
    }
  ]
}