  "document": {
    "title": "SSA-723417: Multiple Vulnerabilities in SCALANCE W1750D",
    "category": "Siemens Security Advisory",
    "csaf_version": "2.0",
    "publisher": {
      "name": "Siemens ProductCERT",
      "contact_details": "productcert@siemens.com",
      "category": "vendor",
      "namespace": "https://www.siemens.com"
    },
    "distribution": {
      "text": "Disclosure is not limited.",
      "tlp": {
        "label": "WHITE"
      }
    },
    "tracking": {
      "id": "SSA-723417",
      "status": "final",
      "version": "3",
      "revision_history": [
        {
          "number": "1",
          "legacy_version": "1.0",
          "date": "2021-05-11T00:00:00Z",
          "summary": "Publication Date"
        },
        {
          "number": "2",
          "legacy_version": "1.1",
          "date": "2021-08-10T00:00:00Z",
          "summary": "Added CVE-2021-34617 and CVE-2021-34618 from updated Aruba Advisory"
        },
        {
          "number": "3",
          "legacy_version": "1.2",
          "date": "2021-10-12T00:00:00Z",
          "summary": "Added solution for SCALANCE W1750D"
        }
      ],
      "initial_release_date": "2021-05-11T00:00:00Z",
      "current_release_date": "2021-10-12T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      }
    },
    "notes": [
      {
        "title": "Summary",
        "category": "summary",
        "text": "The Scalance W1750D device contains multiple vulnerabilities that could allow an attacker to inject commands or trigger buffer overflows.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions."
      },
      {
        "title": "General Recommendations",
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity"
      },
      {
        "title": "Additional Resources",
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories"
      },
      {
        "title": "Terms of Use",
        "category": "legal_disclaimer",
        "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use."
      }
    ],
    "references": [
      {
        "category": "self",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-723417.pdf",
        "summary": "SSA-723417: Multiple Vulnerabilities in SCALANCE W1750D - PDF Version"
      },
      {
        "category": "self",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-723417.txt",
        "summary": "SSA-723417: Multiple Vulnerabilities in SCALANCE W1750D - TXT Version"
      },
      {
        "category": "self",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-723417.json",
        "summary": "SSA-723417: Multiple Vulnerabilities in SCALANCE W1750D - CSAF Version"
      }
    ]
  },
  "product_tree": {
    "branches": [
      {
        "name": "Siemens",
        "category": "vendor",
        "branches": [
          {
            "name": "SCALANCE W1750D",
            "category": "product_name",
            "branches": [
              {
                "name": "< V8.7.0",
                "category": "product_version_range",
                "product": {
                  "product_id": "1",
                  "name": "SCALANCE W1750D"
                }
              }
            ]
          },
          {
            "name": "SCALANCE W1750D",
            "category": "product_name",
            "branches": [
              {
                "name": ">= V8.7.0 and < V8.7.1.3",
                "category": "product_version_range",
                "product": {
                  "product_id": "2",
                  "name": "SCALANCE W1750D"
                }
              }
            ]
          }
        ]
      }
    ]
  },
  "vulnerabilities": [
    {
      "title": "CVE-2019-5317",
      "notes": [
        {
          "title": "Summary",
          "category": "summary",
          "text": "A local authentication bypass vulnerability was discovered in some Aruba Instant Access Point (IAP)."
        }
      ],
      "cve": "CVE-2019-5317",
      "cwe": {
        "id": "CWE-287",
        "name": "Improper Authentication"
      },
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "scores": [
        {
          "cvss_v3": {
            "version": "3.1",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C"
          },
          "products": [
            "1"
          ]
        }
      ],
      "remediations": [
        {
          "product_ids": [
            "1"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.0 or later version",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770"
        },
        {
          "product_ids": [
            "1"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant device IP address on port UDP/8211 from all untrusted users"
        },
        {
          "product_ids": [
            "1"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users"
        },
        {
          "product_ids": [
            "1"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Web Management Interface from all untrusted users"
        }
      ],
      "references": [
        {
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770",
          "summary": "CVE-2019-5317 - SCALANCE W1750D"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-5317.json",
          "summary": "CVE-2019-5317 Mitre 5.0 json"
        }
      ]
    },
    {
      "title": "CVE-2019-5319",
      "notes": [
        {
          "title": "Summary",
          "category": "summary",
          "text": "A remote buffer overflow vulnerability was discovered in some Aruba Instant Access Point (IAP)."
        }
      ],
      "cve": "CVE-2019-5319",
      "cwe": {
        "id": "CWE-120",
        "name": "Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')"
      },
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "scores": [
        {
          "cvss_v3": {
            "version": "3.1",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C"
          },
          "products": [
            "1"
          ]
        }
      ],
      "remediations": [
        {
          "product_ids": [
            "1"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.0 or later version",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770"
        },
        {
          "product_ids": [
            "1"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant device IP address on port UDP/8211 from all untrusted users"
        },
        {
          "product_ids": [
            "1"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users"
        },
        {
          "product_ids": [
            "1"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Web Management Interface from all untrusted users"
        }
      ],
      "references": [
        {
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770",
          "summary": "CVE-2019-5319 - SCALANCE W1750D"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-5319.json",
          "summary": "CVE-2019-5319 Mitre 5.0 json"
        }
      ]
    },
    {
      "title": "CVE-2020-24635",
      "notes": [
        {
          "title": "Summary",
          "category": "summary",
          "text": "A remote execution of arbitrary commands vulnerability was discovered in some Aruba Instant Access Point (IAP)."
        }
      ],
      "cve": "CVE-2020-24635",
      "cwe": {
        "id": "CWE-77",
        "name": "Improper Neutralization of Special Elements used in a Command ('Command Injection')"
      },
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "scores": [
        {
          "cvss_v3": {
            "version": "3.1",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "remediations": [
        {
          "product_ids": [
            "1"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.0 or later version",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770"
        },
        {
          "product_ids": [
            "2"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.1.3 or later version",
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant device IP address on port UDP/8211 from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Web Management Interface from all untrusted users"
        }
      ],
      "references": [
        {
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770",
          "summary": "CVE-2020-24635 - SCALANCE W1750D"
        },
        {
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/",
          "summary": "CVE-2020-24635 - SCALANCE W1750D"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-24635.json",
          "summary": "CVE-2020-24635 Mitre 5.0 json"
        }
      ]
    },
    {
      "title": "CVE-2020-24636",
      "notes": [
        {
          "title": "Summary",
          "category": "summary",
          "text": "A remote execution of arbitrary commands vulnerability was discovered in some Aruba Instant Access Point (IAP)."
        }
      ],
      "cve": "CVE-2020-24636",
      "cwe": {
        "id": "CWE-77",
        "name": "Improper Neutralization of Special Elements used in a Command ('Command Injection')"
      },
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "scores": [
        {
          "cvss_v3": {
            "version": "3.1",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "remediations": [
        {
          "product_ids": [
            "1"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.0 or later version",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770"
        },
        {
          "product_ids": [
            "2"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.1.3 or later version",
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant device IP address on port UDP/8211 from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Web Management Interface from all untrusted users"
        }
      ],
      "references": [
        {
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770",
          "summary": "CVE-2020-24636 - SCALANCE W1750D"
        },
        {
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/",
          "summary": "CVE-2020-24636 - SCALANCE W1750D"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-24636.json",
          "summary": "CVE-2020-24636 Mitre 5.0 json"
        }
      ]
    },
    {
      "title": "CVE-2021-25143",
      "notes": [
        {
          "title": "Summary",
          "category": "summary",
          "text": "A remote Denial of Service (DoS) vulnerability was discovered in some Aruba Instant Access Point (IAP)."
        }
      ],
      "cve": "CVE-2021-25143",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "scores": [
        {
          "cvss_v3": {
            "version": "3.1",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C"
          },
          "products": [
            "1"
          ]
        }
      ],
      "remediations": [
        {
          "product_ids": [
            "1"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.0 or later version",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770"
        },
        {
          "product_ids": [
            "1"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant device IP address on port UDP/8211 from all untrusted users"
        },
        {
          "product_ids": [
            "1"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users"
        },
        {
          "product_ids": [
            "1"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Web Management Interface from all untrusted users"
        }
      ],
      "references": [
        {
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770",
          "summary": "CVE-2021-25143 - SCALANCE W1750D"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25143.json",
          "summary": "CVE-2021-25143 Mitre 5.0 json"
        }
      ]
    },
    {
      "title": "CVE-2021-25144",
      "notes": [
        {
          "title": "Summary",
          "category": "summary",
          "text": "A remote buffer overflow vulnerability was discovered in some Aruba Instant Access Point (IAP)."
        }
      ],
      "cve": "CVE-2021-25144",
      "cwe": {
        "id": "CWE-120",
        "name": "Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')"
      },
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "scores": [
        {
          "cvss_v3": {
            "version": "3.1",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C"
          },
          "products": [
            "1"
          ]
        }
      ],
      "remediations": [
        {
          "product_ids": [
            "1"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.0 or later version",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770"
        },
        {
          "product_ids": [
            "1"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant device IP address on port UDP/8211 from all untrusted users"
        },
        {
          "product_ids": [
            "1"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users"
        },
        {
          "product_ids": [
            "1"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Web Management Interface from all untrusted users"
        }
      ],
      "references": [
        {
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770",
          "summary": "CVE-2021-25144 - SCALANCE W1750D"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25144.json",
          "summary": "CVE-2021-25144 Mitre 5.0 json"
        }
      ]
    },
    {
      "title": "CVE-2021-25145",
      "notes": [
        {
          "title": "Summary",
          "category": "summary",
          "text": "A remote unauthorized disclosure of information vulnerability was discovered in some Aruba Instant Access Point (IAP)."
        }
      ],
      "cve": "CVE-2021-25145",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "scores": [
        {
          "cvss_v3": {
            "version": "3.1",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "remediations": [
        {
          "product_ids": [
            "1"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.0 or later version",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770"
        },
        {
          "product_ids": [
            "2"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.1.3 or later version",
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant device IP address on port UDP/8211 from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Web Management Interface from all untrusted users"
        }
      ],
      "references": [
        {
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770",
          "summary": "CVE-2021-25145 - SCALANCE W1750D"
        },
        {
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/",
          "summary": "CVE-2021-25145 - SCALANCE W1750D"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25145.json",
          "summary": "CVE-2021-25145 Mitre 5.0 json"
        }
      ]
    },
    {
      "title": "CVE-2021-25146",
      "notes": [
        {
          "title": "Summary",
          "category": "summary",
          "text": "A remote execution of arbitrary commands vulnerability was discovered in some Aruba Instant Access Point (IAP)."
        }
      ],
      "cve": "CVE-2021-25146",
      "cwe": {
        "id": "CWE-77",
        "name": "Improper Neutralization of Special Elements used in a Command ('Command Injection')"
      },
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "scores": [
        {
          "cvss_v3": {
            "version": "3.1",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "remediations": [
        {
          "product_ids": [
            "1"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.0 or later version",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770"
        },
        {
          "product_ids": [
            "2"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.1.3 or later version",
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant device IP address on port UDP/8211 from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Web Management Interface from all untrusted users"
        }
      ],
      "references": [
        {
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770",
          "summary": "CVE-2021-25146 - SCALANCE W1750D"
        },
        {
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/",
          "summary": "CVE-2021-25146 - SCALANCE W1750D"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25146.json",
          "summary": "CVE-2021-25146 Mitre 5.0 json"
        }
      ]
    },
    {
      "title": "CVE-2021-25148",
      "notes": [
        {
          "title": "Summary",
          "category": "summary",
          "text": "A remote arbitrary file modification vulnerability was discovered in some Aruba Instant Access Point (IAP)."
        }
      ],
      "cve": "CVE-2021-25148",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "scores": [
        {
          "cvss_v3": {
            "version": "3.1",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H/E:P/RL:O/RC:C"
          },
          "products": [
            "1"
          ]
        }
      ],
      "remediations": [
        {
          "product_ids": [
            "1"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.0 or later version",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770"
        },
        {
          "product_ids": [
            "1"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant device IP address on port UDP/8211 from all untrusted users"
        },
        {
          "product_ids": [
            "1"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users"
        },
        {
          "product_ids": [
            "1"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Web Management Interface from all untrusted users"
        }
      ],
      "references": [
        {
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770",
          "summary": "CVE-2021-25148 - SCALANCE W1750D"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25148.json",
          "summary": "CVE-2021-25148 Mitre 5.0 json"
        }
      ]
    },
    {
      "title": "CVE-2021-25149",
      "notes": [
        {
          "title": "Summary",
          "category": "summary",
          "text": "A remote buffer overflow vulnerability was discovered in some Aruba Instant Access Point (IAP)."
        }
      ],
      "cve": "CVE-2021-25149",
      "cwe": {
        "id": "CWE-120",
        "name": "Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')"
      },
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "scores": [
        {
          "cvss_v3": {
            "version": "3.1",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:U/RC:C"
          },
          "products": [
            "1"
          ]
        }
      ],
      "remediations": [
        {
          "product_ids": [
            "1"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.0 or later version",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770"
        },
        {
          "product_ids": [
            "1"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant device IP address on port UDP/8211 from all untrusted users"
        },
        {
          "product_ids": [
            "1"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users"
        },
        {
          "product_ids": [
            "1"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Web Management Interface from all untrusted users"
        }
      ],
      "references": [
        {
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770",
          "summary": "CVE-2021-25149 - SCALANCE W1750D"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25149.json",
          "summary": "CVE-2021-25149 Mitre 5.0 json"
        }
      ]
    },
    {
      "title": "CVE-2021-25150",
      "notes": [
        {
          "title": "Summary",
          "category": "summary",
          "text": "A remote execution of arbitrary commands vulnerability was discovered in some Aruba Instant Access Point (IAP)."
        }
      ],
      "cve": "CVE-2021-25150",
      "cwe": {
        "id": "CWE-77",
        "name": "Improper Neutralization of Special Elements used in a Command ('Command Injection')"
      },
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "scores": [
        {
          "cvss_v3": {
            "version": "3.1",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C"
          },
          "products": [
            "1"
          ]
        }
      ],
      "remediations": [
        {
          "product_ids": [
            "1"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.0 or later version",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770"
        },
        {
          "product_ids": [
            "1"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant device IP address on port UDP/8211 from all untrusted users"
        },
        {
          "product_ids": [
            "1"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users"
        },
        {
          "product_ids": [
            "1"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Web Management Interface from all untrusted users"
        }
      ],
      "references": [
        {
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770",
          "summary": "CVE-2021-25150 - SCALANCE W1750D"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25150.json",
          "summary": "CVE-2021-25150 Mitre 5.0 json"
        }
      ]
    },
    {
      "title": "CVE-2021-25155",
      "notes": [
        {
          "title": "Summary",
          "category": "summary",
          "text": "A remote arbitrary file modification vulnerability was discovered in some Aruba Instant Access Point (IAP)."
        }
      ],
      "cve": "CVE-2021-25155",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "scores": [
        {
          "cvss_v3": {
            "version": "3.1",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H/E:P/RL:O/RC:C"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "remediations": [
        {
          "product_ids": [
            "1"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.0 or later version",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770"
        },
        {
          "product_ids": [
            "2"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.1.3 or later version",
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant device IP address on port UDP/8211 from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Web Management Interface from all untrusted users"
        }
      ],
      "references": [
        {
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770",
          "summary": "CVE-2021-25155 - SCALANCE W1750D"
        },
        {
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/",
          "summary": "CVE-2021-25155 - SCALANCE W1750D"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25155.json",
          "summary": "CVE-2021-25155 Mitre 5.0 json"
        }
      ]
    },
    {
      "title": "CVE-2021-25156",
      "notes": [
        {
          "title": "Summary",
          "category": "summary",
          "text": "A remote arbitrary directory create vulnerability was discovered in some Aruba Instant Access Point (IAP)."
        }
      ],
      "cve": "CVE-2021-25156",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "scores": [
        {
          "cvss_v3": {
            "version": "3.1",
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "remediations": [
        {
          "product_ids": [
            "1"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.0 or later version",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770"
        },
        {
          "product_ids": [
            "2"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.1.3 or later version",
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant device IP address on port UDP/8211 from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Web Management Interface from all untrusted users"
        }
      ],
      "references": [
        {
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770",
          "summary": "CVE-2021-25156 - SCALANCE W1750D"
        },
        {
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/",
          "summary": "CVE-2021-25156 - SCALANCE W1750D"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25156.json",
          "summary": "CVE-2021-25156 Mitre 5.0 json"
        }
      ]
    },
    {
      "title": "CVE-2021-25157",
      "notes": [
        {
          "title": "Summary",
          "category": "summary",
          "text": "A remote arbitrary file read vulnerability was discovered in some Aruba Instant Access Point (IAP)."
        }
      ],
      "cve": "CVE-2021-25157",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "scores": [
        {
          "cvss_v3": {
            "version": "3.1",
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "remediations": [
        {
          "product_ids": [
            "1"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.0 or later version",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770"
        },
        {
          "product_ids": [
            "2"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.1.3 or later version",
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant device IP address on port UDP/8211 from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Web Management Interface from all untrusted users"
        }
      ],
      "references": [
        {
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770",
          "summary": "CVE-2021-25157 - SCALANCE W1750D"
        },
        {
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/",
          "summary": "CVE-2021-25157 - SCALANCE W1750D"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25157.json",
          "summary": "CVE-2021-25157 Mitre 5.0 json"
        }
      ]
    },
    {
      "title": "CVE-2021-25158",
      "notes": [
        {
          "title": "Summary",
          "category": "summary",
          "text": "A remote arbitrary file read vulnerability was discovered in some Aruba Instant Access Point (IAP)."
        }
      ],
      "cve": "CVE-2021-25158",
      "cwe": {
        "id": "CWE-362",
        "name": "Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition')"
      },
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "scores": [
        {
          "cvss_v3": {
            "version": "3.1",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "remediations": [
        {
          "product_ids": [
            "1"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.0 or later version",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770"
        },
        {
          "product_ids": [
            "2"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.1.3 or later version",
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant device IP address on port UDP/8211 from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Web Management Interface from all untrusted users"
        }
      ],
      "references": [
        {
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770",
          "summary": "CVE-2021-25158 - SCALANCE W1750D"
        },
        {
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/",
          "summary": "CVE-2021-25158 - SCALANCE W1750D"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25158.json",
          "summary": "CVE-2021-25158 Mitre 5.0 json"
        }
      ]
    },
    {
      "title": "CVE-2021-25159",
      "notes": [
        {
          "title": "Summary",
          "category": "summary",
          "text": "A remote arbitrary file modification vulnerability was discovered in some Aruba Instant Access Point (IAP)."
        }
      ],
      "cve": "CVE-2021-25159",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "scores": [
        {
          "cvss_v3": {
            "version": "3.1",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H/E:P/RL:O/RC:C"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "remediations": [
        {
          "product_ids": [
            "1"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.0 or later version",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770"
        },
        {
          "product_ids": [
            "2"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.1.3 or later version",
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant device IP address on port UDP/8211 from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Web Management Interface from all untrusted users"
        }
      ],
      "references": [
        {
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770",
          "summary": "CVE-2021-25159 - SCALANCE W1750D"
        },
        {
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/",
          "summary": "CVE-2021-25159 - SCALANCE W1750D"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25159.json",
          "summary": "CVE-2021-25159 Mitre 5.0 json"
        }
      ]
    },
    {
      "title": "CVE-2021-25160",
      "notes": [
        {
          "title": "Summary",
          "category": "summary",
          "text": "A remote arbitrary file modification vulnerability was discovered in some Aruba Instant Access Point (IAP)."
        }
      ],
      "cve": "CVE-2021-25160",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "scores": [
        {
          "cvss_v3": {
            "version": "3.1",
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "remediations": [
        {
          "product_ids": [
            "1"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.0 or later version",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770"
        },
        {
          "product_ids": [
            "2"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.1.3 or later version",
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant device IP address on port UDP/8211 from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Web Management Interface from all untrusted users"
        }
      ],
      "references": [
        {
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770",
          "summary": "CVE-2021-25160 - SCALANCE W1750D"
        },
        {
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/",
          "summary": "CVE-2021-25160 - SCALANCE W1750D"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25160.json",
          "summary": "CVE-2021-25160 Mitre 5.0 json"
        }
      ]
    },
    {
      "title": "CVE-2021-25161",
      "notes": [
        {
          "title": "Summary",
          "category": "summary",
          "text": "A remote cross-site scripting (xss) vulnerability was discovered in some Aruba Instant Access Point (IAP)."
        }
      ],
      "cve": "CVE-2021-25161",
      "cwe": {
        "id": "CWE-79",
        "name": "Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')"
      },
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "scores": [
        {
          "cvss_v3": {
            "version": "3.1",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:O/RC:C"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "remediations": [
        {
          "product_ids": [
            "1"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.0 or later version",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770"
        },
        {
          "product_ids": [
            "2"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.1.3 or later version",
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant device IP address on port UDP/8211 from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Web Management Interface from all untrusted users"
        }
      ],
      "references": [
        {
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770",
          "summary": "CVE-2021-25161 - SCALANCE W1750D"
        },
        {
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/",
          "summary": "CVE-2021-25161 - SCALANCE W1750D"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25161.json",
          "summary": "CVE-2021-25161 Mitre 5.0 json"
        }
      ]
    },
    {
      "title": "CVE-2021-25162",
      "notes": [
        {
          "title": "Summary",
          "category": "summary",
          "text": "A remote execution of arbitrary commands vulnerability was discovered in some Aruba Instant Access Point (IAP)."
        }
      ],
      "cve": "CVE-2021-25162",
      "cwe": {
        "id": "CWE-77",
        "name": "Improper Neutralization of Special Elements used in a Command ('Command Injection')"
      },
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "scores": [
        {
          "cvss_v3": {
            "version": "3.1",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "remediations": [
        {
          "product_ids": [
            "1"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.0 or later version",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770"
        },
        {
          "product_ids": [
            "2"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.1.3 or later version",
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant device IP address on port UDP/8211 from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Web Management Interface from all untrusted users"
        }
      ],
      "references": [
        {
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770",
          "summary": "CVE-2021-25162 - SCALANCE W1750D"
        },
        {
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/",
          "summary": "CVE-2021-25162 - SCALANCE W1750D"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25162.json",
          "summary": "CVE-2021-25162 Mitre 5.0 json"
        }
      ]
    },
    {
      "title": "CVE-2021-34617",
      "notes": [
        {
          "title": "Summary",
          "category": "summary",
          "text": "A vulnerability in the captive portal of Aruba Instant could allow an unauthenticated remote attacker to conduct a reflected cross-site scripting (XSS) attack against another user of the portal. A successful exploit could allow an attacker to execute arbitrary script code in a victim’s browser in the context of the affected interface."
        }
      ],
      "cve": "CVE-2021-34617",
      "cwe": {
        "id": "CWE-80",
        "name": "Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
      },
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "scores": [
        {
          "cvss_v3": {
            "version": "3.1",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:O/RC:C"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "remediations": [
        {
          "product_ids": [
            "1"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.0 or later version",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770"
        },
        {
          "product_ids": [
            "2"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.1.3 or later version",
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant device IP address on port UDP/8211 from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Web Management Interface from all untrusted users"
        }
      ],
      "references": [
        {
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770",
          "summary": "CVE-2021-34617 - SCALANCE W1750D"
        },
        {
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/",
          "summary": "CVE-2021-34617 - SCALANCE W1750D"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-34617.json",
          "summary": "CVE-2021-34617 Mitre 5.0 json"
        }
      ]
    },
    {
      "title": "CVE-2021-34618",
      "notes": [
        {
          "title": "Summary",
          "category": "summary",
          "text": "An unauthenticated Denial of Service vulnerability exists in affected Aruba Instant access points. Exploitation of this vulnerability is only possible via direct ethernet connection to the access point. This vulnerability can be exploited through the LLDP protocol and successful exploitation results in the unavailability of the affected access point due to resource exhaustion."
        }
      ],
      "cve": "CVE-2021-34618",
      "cwe": {
        "id": "CWE-400",
        "name": "Uncontrolled Resource Consumption"
      },
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "scores": [
        {
          "cvss_v3": {
            "version": "3.1",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "remediations": [
        {
          "product_ids": [
            "1"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.0 or later version",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770"
        },
        {
          "product_ids": [
            "2"
          ],
          "category": "vendor_fix",
          "details": "Update to V8.7.1.3 or later version",
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant device IP address on port UDP/8211 from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Command Line Interface from all untrusted users"
        },
        {
          "product_ids": [
            "1",
            "2"
          ],
          "category": "mitigation",
          "details": "Block access to the Aruba Instant Web Management Interface from all untrusted users"
        }
      ],
      "references": [
        {
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109782770",
          "summary": "CVE-2021-34618 - SCALANCE W1750D"
        },
        {
          "url": "https://support.industry.siemens.com/cs/de/en/view/109802805/",
          "summary": "CVE-2021-34618 - SCALANCE W1750D"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-34618.json",
          "summary": "CVE-2021-34618 Mitre 5.0 json"
        }
      ]
    }
  ]
}