  "document": {
    "title": "SSA-292794: Multiple Denial-of-Service Vulnerabilities in SINEMA Remote Connect Server",
    "category": "Siemens Security Advisory",
    "csaf_version": "2.0",
    "publisher": {
      "name": "Siemens ProductCERT",
      "contact_details": "productcert@siemens.com",
      "category": "vendor",
      "namespace": "https://www.siemens.com"
    },
    "distribution": {
      "text": "Disclosure is not limited.",
      "tlp": {
        "label": "WHITE"
      }
    },
    "tracking": {
      "id": "SSA-292794",
      "status": "final",
      "version": "1",
      "revision_history": [
        {
          "number": "1",
          "legacy_version": "1.0",
          "date": "2021-04-13T00:00:00Z",
          "summary": "Publication Date"
        }
      ],
      "initial_release_date": "2021-04-13T00:00:00Z",
      "current_release_date": "2021-04-13T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      }
    },
    "notes": [
      {
        "title": "Summary",
        "category": "summary",
        "text": "The latest update for SINEMA Remote Connect Server fixes two Denial-of-Service vulnerabilities in the underlying third-party XML parser.\n\nSiemens has released updates for the affected product and recommends to update to the latest versions."
      },
      {
        "title": "General Recommendations",
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity"
      },
      {
        "title": "Additional Resources",
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories"
      },
      {
        "title": "Terms of Use",
        "category": "legal_disclaimer",
        "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use."
      }
    ],
    "references": [
      {
        "category": "self",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-292794.pdf",
        "summary": "SSA-292794: Multiple Denial-of-Service Vulnerabilities in SINEMA Remote Connect Server - PDF Version"
      },
      {
        "category": "self",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-292794.txt",
        "summary": "SSA-292794: Multiple Denial-of-Service Vulnerabilities in SINEMA Remote Connect Server - TXT Version"
      },
      {
        "category": "self",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-292794.json",
        "summary": "SSA-292794: Multiple Denial-of-Service Vulnerabilities in SINEMA Remote Connect Server - CSAF Version"
      }
    ]
  },
  "product_tree": {
    "branches": [
      {
        "name": "Siemens",
        "category": "vendor",
        "branches": [
          {
            "name": "SINEMA Remote Connect Server",
            "category": "product_name",
            "branches": [
              {
                "name": "< V3.0",
                "category": "product_version_range",
                "product": {
                  "product_id": "1",
                  "name": "SINEMA Remote Connect Server"
                }
              }
            ]
          }
        ]
      }
    ]
  },
  "vulnerabilities": [
    {
      "title": "CVE-2019-19956",
      "notes": [
        {
          "title": "Summary",
          "category": "summary",
          "text": "xmlParseBalancedChunkMemoryRecover in parser.c in libxml2 before 2.9.10 has a memory leak related to newDoc->oldNs."
        }
      ],
      "cve": "CVE-2019-19956",
      "cwe": {
        "id": "CWE-772",
        "name": "Missing Release of Resource after Effective Lifetime"
      },
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "scores": [
        {
          "cvss_v3": {
            "version": "3.1",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C"
          },
          "products": [
            "1"
          ]
        }
      ],
      "remediations": [
        {
          "product_ids": [
            "1"
          ],
          "category": "vendor_fix",
          "details": "Update to V3.0",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109793790"
        }
      ],
      "references": [
        {
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109793790",
          "summary": "CVE-2019-19956 - SINEMA Remote Connect Server"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-19956.json",
          "summary": "CVE-2019-19956 Mitre 5.0 json"
        }
      ]
    },
    {
      "title": "CVE-2020-7595",
      "notes": [
        {
          "title": "Summary",
          "category": "summary",
          "text": "xmlStringLenDecodeEntities in parser.c in libxml2 2.9.10 has an infinite loop in a certain end-of-file situation."
        }
      ],
      "cve": "CVE-2020-7595",
      "cwe": {
        "id": "CWE-835",
        "name": "Loop with Unreachable Exit Condition ('Infinite Loop')"
      },
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "scores": [
        {
          "cvss_v3": {
            "version": "3.1",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C"
          },
          "products": [
            "1"
          ]
        }
      ],
      "remediations": [
        {
          "product_ids": [
            "1"
          ],
          "category": "vendor_fix",
          "details": "Update to V3.0",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109793790"
        }
      ],
      "references": [
        {
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109793790",
          "summary": "CVE-2020-7595 - SINEMA Remote Connect Server"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-7595.json",
          "summary": "CVE-2020-7595 Mitre 5.0 json"
        }
      ]
    }
  ]
}